Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Front Neurosci ; 17: 987578, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36816118

RESUMO

Introduction: A device comprising two generic earpieces with embedded dry electrodes for ear-centered electroencephalography (ear-EEG) was developed. The objective was to provide ear-EEG based sleep monitoring to a wide range of the population without tailoring the device to the individual. Methods: To validate the device ten healthy subjects were recruited for a 12-night sleep study. The study was divided into two parts; part A comprised two nights with both ear-EEG and polysomnography (PSG), and part B comprised 10 nights using only ear-EEG. In addition to the electrophysiological measurements, subjects filled out a questionnaire after each night of sleep. Results: The subjects reported that the ear-EEG system was easy to use, and that the comfort was better in part B. The performance of the system was validated by comparing automatic sleep scoring based on ear-EEG with PSG-based sleep scoring performed by a professional trained sleep scorer. Cohen's kappa was used to assess the agreement between the manual and automatic sleep scorings, and the study showed an average kappa value of 0.71. The majority of the 20 recordings from part A yielded a kappa value above 0.7. The study was compared to a companioned study conducted with individualized earpieces. To compare the sleep across the two studies and two parts, 7 different sleeps metrics were calculated based on the automatic sleep scorings. The ear-EEG nights were validated through linear mixed model analysis in which the effects of equipment (individualized vs. generic earpieces), part (PSG and ear-EEG vs. only ear-EEG) and subject were investigated. We found that the subject effect was significant for all computed sleep metrics. Furthermore, the equipment did not show any statistical significant effect on any of the sleep metrics. Discussion: These results corroborate that generic ear-EEG is a promising alternative to the gold standard PSG for sleep stage monitoring. This will allow sleep stage monitoring to be performed in a less obtrusive way and over longer periods of time, thereby enabling diagnosis and treatment of diseases with associated sleep disorders.

2.
IEEE Trans Biomed Eng ; 70(4): 1264-1273, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36227816

RESUMO

OBJECTIVE: The purpose of this study was to investigate alpha power as an objective measure of effortful listening in continuous speech with scalp and ear-EEG. METHODS: Scalp and ear-EEG were recorded simultaneously during presentation of a 33-s news clip in the presence of 16-talker babble noise. Four different signal-to-noise ratios (SNRs) were used to manipulate task demand. The effects of changes in SNR were investigated on alpha event-related synchronization (ERS) and desynchronization (ERD). Alpha activity was extracted from scalp EEG using different referencing methods (common average and symmetrical bi-polar) in different regions of the brain (parietal and temporal) and ear-EEG. RESULTS: Alpha ERS decreased with decreasing SNR (i.e., increasing task demand) in both scalp and ear-EEG. Alpha ERS was also positively correlated to behavioural performance which was based on the questions regarding the contents of the speech. CONCLUSION: Alpha ERS/ERD is better suited to track performance of a continuous speech than listening effort. SIGNIFICANCE: EEG alpha power in continuous speech may indicate of how well the speech was perceived and it can be measured with both scalp and Ear-EEG.


Assuntos
Couro Cabeludo , Fala , Eletroencefalografia , Percepção Auditiva , Auscultação
3.
Annu Int Conf IEEE Eng Med Biol Soc ; 2022: 3135-3138, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-36085914

RESUMO

High quality sleep monitoring is done using EEG electrodes placed on the skin. This has traditionally required assistance by an expert when the equipment needed to mounted. However, this creates a limitation in how cheap and easy it can be to record sleep in the subject's own home. Here we present a data set of 120 home recordings of sleep, in which subjects use self-applied ear-EEG monitoring equipment. We compare this data set to a previously recorded data set with both ear-EEG and polysomnography, which was applied by an expert. Clinical relevance - On all tested metrics, self applied sleep recordings behaved the same as expert applied. This indicates that ear-EEG can reliably be used as a home sleep monitor, even when subjects apply the equipment themselves.


Assuntos
Sono , Dispositivos Eletrônicos Vestíveis , Eletrodos , Eletroencefalografia , Humanos , Polissonografia
4.
IEEE Trans Biomed Eng ; 69(5): 1564-1572, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-34587000

RESUMO

Modern sleep monitoring development is shifting towards the use of unobtrusive sensors combined with algorithms for automatic sleep scoring. Many different combinations of wet and dry electrodes, ear-centered, forehead-mounted or headband-inspired designs have been proposed, alongside an ever growing variety of machine learning algorithms for automatic sleep scoring. OBJECTIVE: Among candidate positions, those in the facial area and around the ears have the benefit of being relatively hairless, and in our view deserve extra attention. In this paper, we seek to determine the limits to sleep monitoring quality within this spatial constraint. METHODS: We compare 13 different, realistic sensor setups derived from the same data set and analysed with the same pipeline. RESULTS: All setups which include both a lateral and an EOG derivation show similar, state-of-the-art performance, with average Cohen's kappa values of at least 0.80. CONCLUSION: If large electrode distances are used, positioning is not critical for achieving large sleep-related signal-to-noise-ratio, and hence accurate sleep scoring. SIGNIFICANCE: We argue that with the current competitive performance of automated staging approaches, there is a need for establishing an improved benchmark beyond current single human rater scoring.


Assuntos
Eletroencefalografia , Fases do Sono , Algoritmos , Eletrodos , Humanos , Polissonografia , Sono
5.
Sci Rep ; 9(1): 16824, 2019 11 14.
Artigo em Inglês | MEDLINE | ID: mdl-31727953

RESUMO

Sleep is a key phenomenon to both understanding, diagnosing and treatment of many illnesses, as well as for studying health and well being in general. Today, the only widely accepted method for clinically monitoring sleep is the polysomnography (PSG), which is, however, both expensive to perform and influences the sleep. This has led to investigations into light weight electroencephalography (EEG) alternatives. However, there has been a substantial performance gap between proposed alternatives and PSG. Here we show results from an extensive study of 80 full night recordings of healthy participants wearing both PSG equipment and ear-EEG. We obtain automatic sleep scoring with an accuracy close to that achieved by manual scoring of scalp EEG (the current gold standard), using only ear-EEG as input, attaining an average Cohen's kappa of 0.73. In addition, this high performance is present for all 20 subjects. Finally, 19/20 subjects found that the ear-EEG had little to no negative effect on their sleep, and subjects were generally able to apply the equipment without supervision. This finding marks a turning point on the road to clinical long term sleep monitoring: the question should no longer be whether ear-EEG could ever be used for clinical home sleep monitoring, but rather when it will be.


Assuntos
Eletroencefalografia/instrumentação , Polissonografia/instrumentação , Sono/fisiologia , Adulto , Desenho de Equipamento , Feminino , Voluntários Saudáveis , Humanos , Masculino , Adulto Jovem
6.
IEEE Trans Biomed Eng ; 66(1): 150-158, 2019 01.
Artigo em Inglês | MEDLINE | ID: mdl-29993415

RESUMO

OBJECTIVE: Ear-EEG is a recording method in which EEG signals are acquired from electrodes placed on an earpiece inserted into the ear. Thereby, ear-EEG provides a noninvasive and discreet way of recording EEG, and has the potential to be used for long-term brain monitoring in real-life environments. Whereas previously reported ear-EEG recordings have been performed with wet electrodes, the objective of this study was to develop and evaluate dry-contact electrode ear-EEG. METHODS: To achieve a well-functioning dry-contact interface, a new ear-EEG platform was developed. The platform comprised actively shielded and nanostructured electrodes embedded in an individualized soft-earpiece. The platform was evaluated in a study of 12 subjects and four EEG paradigms: auditory steady-state response, steady-state visual evoked potential, mismatch negativity, and alpha-band modulation. RESULTS: Recordings from the prototyped dry-contact ear-EEG platform were compared to conventional scalp EEG recordings. When all electrodes were referenced to a common scalp electrode (Cz), the performance was on par with scalp EEG measured close to the ear. With both the measuring electrode and the reference electrode located within the ear, statistically significant (p < 0.05) responses were measured for all paradigms, although for mismatch negativity, it was necessary to use a reference located in the opposite ear, to obtain a statistically significant response. CONCLUSION: The study demonstrated that dry-contact electrode ear-EEG is a feasible technology for EEG recording. SIGNIFICANCE: The prototyped dry-contact ear-EEG platform represents an important technological advancement of the method in terms of user-friendliness, because it eliminates the need for gel in the electrode-skin interface.


Assuntos
Orelha Externa/fisiologia , Eletroencefalografia/instrumentação , Monitorização Ambulatorial/instrumentação , Dispositivos Eletrônicos Vestíveis , Adulto , Eletrodos , Humanos , Irídio , Desenho de Prótese , Processamento de Sinais Assistido por Computador/instrumentação
7.
Annu Int Conf IEEE Eng Med Biol Soc ; 2019: 6697-6700, 2019 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31947378

RESUMO

Sleep spindles are brief oscillatory events observed in EEG measurements during sleep, related to both sleep staging and basic neuroscience. The objective of this study was to investigate to which extent sleep spindles are observable from ear-EEG. The analysis was based on single-night recordings from 12 subjects, wearing both a polysomnography setup and two light-weight mobile EEG devices (ear-EEG). By introducing a sleep spindle index capable of discriminating between epochs with distinct spindles and distinctly spindle-free epochs, we describe to which extent the most clear cut sleep spindles (as labeled using scalp EEG) can be detected using ear-EEG. We find that ear-EEG can be used to detect sleep spindles, at a performance level similar to scalp derivations. We speculate that part of the observed discrepancy between ear-EEG and the gold standard (scalp EEG) could be caused by the visibility of different spindles in the ear-EEG.


Assuntos
Sono , Eletroencefalografia , Humanos , Polissonografia , Couro Cabeludo
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...